Build 66(8/21/2015)
- Variable Browser relocated location path field next to variable name (4660)
Build 65(3/30/2015)
- Variable Browser Select All button no longer selects filtered variables (4582)
- Variable Browser now displays location path (4582)
Build 64 (7/3/2014)
- Additional logging added (4159)
- Added a database connection throttle allowing other processes (programs) to process events to run. (4267)
- Variable Browser improvements - added quick filter, filter by facility. (4385)
- Variable Browser UI improvement for Windows 7 (4466)
Build 60
- Added support for MAXTIME and MINTIME to the import process.(4185)
- Fixed problem importing text values.(4125)
- Added user option setting to keep the database connection open during the entire import process.(4106)
Build 57
- Added a global variable to CommonGlobals to allow custom notes to the stats summary at the end of a run. I added the global variable to CommonGlobals and it is used in CommonImport (4132)
Build 56
- Added a global variable to CommonGlobals and CommonImport to keep the CustomImport object alive so its connection would stay open. We were having a problem with a special database driver hanging when it was closed. (4106)
Build 55
- Fixed framework to properly handle Text Parameter type variables (4125)
Build 53
- Updated framework to handle time zone differences and how they affect direct and indirect interfaces
Build 47
- Added logging in CommTAGFilter routine CarryLastValue when verbosity is set to 9
Build 46
- Changed CommonImport to make sure start date is correct when using the Cache feature in Advanced Settings (only affects certain interfaces) (3261)
- Changed CommonTAGFilter to scrutinize data returned from CustomTAGFilter (only affects certain interfaces) (3313)
- Changed CommonTAGFilter to propogate execution error check down to lowest level, so that we can distinguish between an execution error and bad data (only affects certain interfaces) (3426)
Build 41
- Added to CommonTypeDateManager in Common_SCADA2OPSSQL; added code to compensate for daily var that have less than 1440 min/slot (i.e., 60 min from total day) so that it would get current day if the start and stop times have passed current time (Fortress 2673)
Build 40
- Added ability to view connection string in CustomConfig form
Build 37
- Added ability for SCADA2OPSSQL type of interfaces to define a global configuration tree
Build 36
- Fixed problem with statistics TIMELT, TIMEGT, and TIMEEQ not counting the very first record.
Build 34
- Added to caching function to support the following statistics for parameters using flat file databases: TOTAL, AVERAGE, MINIMUM, MAXIMUM, FIRST, LAST, DIFF, RANGE, COUNT, INVENTORY, TIMEGT, TIMELT, and TIMEEQ
- Added to caching function to support the following statistics for text parameters using flat file databases: MINTIME, MAXTIME, FIRST, LAST, COUNT
- Added to caching function to support the following filter operators on filter tags when using flat file databases: =, <, >, <=, >=, <>, and CYCLESTO
(Note: consult the "Topic specific to the operation of this interface" article "Supported Variable Configuration" to see whether your interface supports these available options or not)
Build 28
- Added ability to specify adjustment of start date in minutes when running in automated mode. This can be configured under Configuration / Automated Import Configuration (2445)
- Added support for caching of input to accelerate interface performance of interface that rely heavily on IO (2481)
- Added support for filtering for OLEDB types of SCADA2OPSSQL interfaces (2457)
Build 10
- Initial Release to Public
|
|
|
|